Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.081
Filtrar
1.
Medicine (Baltimore) ; 103(15): e37852, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608060

RESUMO

RATIONALE: Serotonin syndrome is a potentially life-threatening condition resulting from the use of antidepressants, their interactions with other serotonergic medications, or poisoning. It presents with a triad of psychiatric, dysautonomic, and neurological symptoms and is sometimes fatal. While cyproheptadine is a specific treatment option, the optimal duration of its administration remains unclear. The purpose of this report is to quantitatively assess the endpoints of serotonin syndrome treatment. Based on the hypothesis that neurological pupil index (NPi) on a digital pupil recorder would correlate with the severity of the serotonin syndrome, we administered cyproheptadine using NPi as an indicator. PATIENT CONCERNS: A patient with a history of depression was brought to our hospital after he overdosed on 251 tablets of serotonin and noradrenaline reuptake inhibitors. DIAGNOSES: On day 3, the patient was diagnosed with serotonin syndrome. INTERVENTIONS: Cyproheptadine syrup was administered at 4 mg every 4 hours. The NPi of the automated pupillometer was simultaneously measured. On day 5, the NPi exceeded 3.0 cyproheptadine was discontinued. OUTCOMES: The patient was discharged on day 7. LESSONS: The lack of considerable improvement during the treatment period suggests that the patient may have improved on his own. In this case, the relationship between NPi and the severity of serotonin syndrome could not be determined.


Assuntos
Doenças do Sistema Nervoso Autônomo , Síndrome da Serotonina , Masculino , Humanos , Síndrome da Serotonina/diagnóstico , Síndrome da Serotonina/tratamento farmacológico , Pupila , Serotonina , Ciproeptadina/uso terapêutico
2.
Trends Hear ; 28: 23312165241245240, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38613337

RESUMO

Listening to speech in noise can require substantial mental effort, even among younger normal-hearing adults. The task-evoked pupil response (TEPR) has been shown to track the increased effort exerted to recognize words or sentences in increasing noise. However, few studies have examined the trajectory of listening effort across longer, more natural, stretches of speech, or the extent to which expectations about upcoming listening difficulty modulate the TEPR. Seventeen younger normal-hearing adults listened to 60-s-long audiobook passages, repeated three times in a row, at two different signal-to-noise ratios (SNRs) while pupil size was recorded. There was a significant interaction between SNR, repetition, and baseline pupil size on sustained listening effort. At lower baseline pupil sizes, potentially reflecting lower attention mobilization, TEPRs were more sustained in the harder SNR condition, particularly when attention mobilization remained low by the third presentation. At intermediate baseline pupil sizes, differences between conditions were largely absent, suggesting these listeners had optimally mobilized their attention for both SNRs. Lastly, at higher baseline pupil sizes, potentially reflecting overmobilization of attention, the effect of SNR was initially reversed for the second and third presentations: participants initially appeared to disengage in the harder SNR condition, resulting in reduced TEPRs that recovered in the second half of the story. Together, these findings suggest that the unfolding of listening effort over time depends critically on the extent to which individuals have successfully mobilized their attention in anticipation of difficult listening conditions.


Assuntos
Esforço de Escuta , Pupila , Adulto , Humanos , Razão Sinal-Ruído , Fala
3.
Sci Rep ; 14(1): 8739, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627572

RESUMO

Inspired by recent findings in the visual domain, we investigated whether the stimulus-evoked pupil dilation reflects temporal statistical regularities in sequences of auditory stimuli. We conducted two preregistered pupillometry experiments (experiment 1, n = 30, 21 females; experiment 2, n = 31, 22 females). In both experiments, human participants listened to sequences of spoken vowels in two conditions. In the first condition, the stimuli were presented in a random order and, in the second condition, the same stimuli were presented in a sequence structured in pairs. The second experiment replicated the first experiment with a modified timing and number of stimuli presented and without participants being informed about any sequence structure. The sound-evoked pupil dilation during a subsequent familiarity task indicated that participants learned the auditory vowel pairs of the structured condition. However, pupil diameter during the structured sequence did not differ according to the statistical regularity of the pair structure. This contrasts with similar visual studies, emphasizing the susceptibility of pupil effects during statistically structured sequences to experimental design settings in the auditory domain. In sum, our findings suggest that pupil diameter may serve as an indicator of sound pair familiarity but does not invariably respond to task-irrelevant transition probabilities of auditory sequences.


Assuntos
Pupila , Som , Feminino , Humanos , Pupila/fisiologia , Reconhecimento Psicológico , Percepção Auditiva/fisiologia
4.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593257

RESUMO

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Assuntos
Astigmatismo , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Córnea , Pupila , Biometria , Topografia da Córnea , Refração Ocular
5.
Cogn Sci ; 48(4): e13446, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38655881

RESUMO

Understanding cognitive effort expended during assessments is essential to improving efficiency, accuracy, and accessibility within these assessments. Pupil dilation is commonly used as a psychophysiological measure of cognitive effort, yet research on its relationship with effort expended specifically during language processing is limited. The present study adds to and expands on this literature by investigating the relationships among pupil dilation, trial difficulty, and accuracy during a vocabulary test. Participants (n = 63, Mage = 19.25) completed a subset of trials from the Peabody Picture Vocabulary Test while seated at an eye-tracker monitor. During each trial, four colored images were presented on the monitor while a word was presented via audio recording. Participants verbally indicated which image they thought represented the target word. Words were categorized into Easy, Medium, and Hard difficulty. Pupil dilation during the Medium and Hard trials was significantly greater than during the Easy trials, though the Medium and Hard trials did not significantly differ from each other. Pupil dilation in comparison to trial accuracy presented a more complex pattern, with comparisons between accurate and inaccurate trials differing depending on the timing of the stimulus presentation. These results present further evidence that pupil dilation increases with cognitive effort associated with vocabulary tests, providing insights that could help refine vocabulary assessments and other related tests of language processing.


Assuntos
Pupila , Vocabulário , Humanos , Pupila/fisiologia , Masculino , Feminino , Adulto Jovem , Cognição/fisiologia , Adolescente , Adulto , Testes de Linguagem
6.
Sci Rep ; 14(1): 9418, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658628

RESUMO

Pupil contagion refers to the observer's pupil-diameter changes in response to changes in the pupil diameter of others. Recent studies on the other-race effect on pupil contagion have mainly focused on using eye region images as stimuli, revealing the effect in adults but not in infants. To address this research gap, the current study used whole-face images as stimuli to assess the pupil-diameter response of 5-6-month-old and 7-8-month-old infants to changes in the pupil-diameter of both upright and inverted unfamiliar-race faces. The study initially hypothesized that there would be no pupil contagion in either upright or inverted unfamiliar-race faces, based on our previous finding of pupil contagion occurring only in familiar-race faces among 5-6-month-old infants. Notably, the current results indicated that 5-6-month-old infants exhibited pupil contagion in both upright and inverted unfamiliar-race faces, while 7-8-month-old infants showed this effect only in upright unfamiliar-race faces. These results demonstrate that the face inversion effect of pupil contagion does not occur in 5-6-month-old infants, thereby suggesting the presence of the other-race effect in pupil contagion among this age group. Overall, this study provides the first evidence of the other-race effect on infants' pupil contagion using face stimuli.


Assuntos
Pupila , Humanos , Pupila/fisiologia , Lactente , Masculino , Feminino , Estimulação Luminosa , Reconhecimento Facial/fisiologia
7.
Nat Commun ; 15(1): 3141, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653975

RESUMO

Brightness illusions are a powerful tool in studying vision, yet their neural correlates are poorly understood. Based on a human paradigm, we presented illusory drifting gratings to mice. Primary visual cortex (V1) neurons responded to illusory gratings, matching their direction selectivity for real gratings, and they tracked the spatial phase offset between illusory and real gratings. Illusion responses were delayed compared to real gratings, in line with the theory that processing illusions requires feedback from higher visual areas (HVAs). We provide support for this theory by showing a reduced V1 response to illusions, but not real gratings, following HVAs optogenetic inhibition. Finally, we used the pupil response (PR) as an indirect perceptual report and showed that the mouse PR matches the human PR to perceived luminance changes. Our findings resolve debates over whether V1 neurons are involved in processing illusions and highlight the involvement of feedback from HVAs.


Assuntos
Neurônios , Optogenética , Estimulação Luminosa , Córtex Visual Primário , Animais , Neurônios/fisiologia , Córtex Visual Primário/fisiologia , Camundongos , Masculino , Humanos , Feminino , Percepção Visual/fisiologia , Ilusões/fisiologia , Ilusões Ópticas/fisiologia , Camundongos Endogâmicos C57BL , Pupila/fisiologia , Córtex Visual/fisiologia , Córtex Visual/citologia
8.
Transl Vis Sci Technol ; 13(4): 23, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38630470

RESUMO

Purpose: The common protocol of full-field stimulus threshold (FST) testing recommends pupil dilation. The aim of this study is to investigate the difference between FST measurements with dilated and nondilated pupils in healthy subjects and patients with retinitis pigmentosa (RP). Methods: Twenty healthy subjects and 20 RP patients were selected. One pupil of each subject was dilated; the other eye was measured in physiological width of the pupil. The FST was conducted using Diagnosys Espion E2/E3 with white, blue, and red stimuli. Statistical analysis was conducted with a mixed-model analysis of variance and a paired t-test. Results: The statistical analysis revealed a significant difference between measurements of dilated and nondilated pupils with the following: blue stimuli for all subjects and groups except those with highly progressed RP; white stimuli for all tested subjects in total, for RP patients with better-preserved visual field (VF), and rod-mediated FST response; and red stimuli for RP patients with better-preserved VF and rod-mediated FST response. On average, the difference between the FST values for RP patients were -3.2 ± 3 dB for blue, -2.3 ± 2.9 dB for white, and -0.83 ± 3 dB for red stimuli. The correlation between the FST values of dilated and nondilated pupils with all three stimuli was linear. Conclusions: Current recommendations are to perform FST with dilated pupils. However, based on this study's findings, pupil dilation can be omitted for clinical diagnostics or rough follow-ups. Translational Relevance: Our data provide useful information for the clinical use of FST.


Assuntos
Pupila , Retinite Pigmentosa , Humanos , Voluntários Saudáveis , Projetos de Pesquisa , Retinite Pigmentosa/diagnóstico , Campos Visuais
9.
Sci Rep ; 14(1): 9221, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649681

RESUMO

Technological advances in head-mounted displays (HMDs) facilitate the acquisition of physiological data of the user, such as gaze, pupil size, or heart rate. Still, interactions with such systems can be prone to errors, including unintended behavior or unexpected changes in the presented virtual environments. In this study, we investigated if multimodal physiological data can be used to decode error processing, which has been studied, to date, with brain signals only. We examined the feasibility of decoding errors solely with pupil size data and proposed a hybrid decoding approach combining electroencephalographic (EEG) and pupillometric signals. Moreover, we analyzed if hybrid approaches can improve existing EEG-based classification approaches and focused on setups that offer increased usability for practical applications, such as the presented game-like virtual reality flight simulation. Our results indicate that classifiers trained with pupil size data can decode errors above chance. Moreover, hybrid approaches yielded improved performance compared to EEG-based decoders in setups with a reduced number of channels, which is crucial for many out-of-the-lab scenarios. These findings contribute to the development of hybrid brain-computer interfaces, particularly in combination with wearable devices, which allow for easy acquisition of additional physiological data.


Assuntos
Interfaces Cérebro-Computador , Eletroencefalografia , Pupila , Realidade Virtual , Humanos , Eletroencefalografia/métodos , Adulto , Masculino , Pupila/fisiologia , Feminino , Adulto Jovem , Simulação por Computador , Encéfalo/fisiologia , Frequência Cardíaca/fisiologia
10.
Sci Rep ; 14(1): 7843, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570565

RESUMO

Previous work has shown divergent pupil dilation (PD) and gaze behavior in individuals with autism spectrum disorder (ASD), which may relate to the development of social difficulties in early life. Here, we investigated temporal dynamics of both phenotypes during naturalistic videos of a person displaying facial emotion expressions in 61 autistic and 61 non-autistic preschoolers. PD was segmented into three serial time components derived from a principal component analysis. Growth curve analysis was applied to analyze changes in looking time on eye and mouth regions over time. Groups did not differ in PD time components. Growth curve analysis revealed initially shorter looking times on the eyes and longer looking times on the mouth in autistic versus non-autistic preschoolers. However, a reversion of this pattern was observed over time, suggesting a delayed compensatory increase in eye attention during prolonged viewing periods in autistic children. Positive and negative associations of PD components and gaze behavior over time indicated a dynamic temporal relationship during emotion viewing. Our findings emphasize the need to apply time-sensitive measures in ecologically valid research, which may index etiological mechanisms of social difficulties in ASD.


Assuntos
Transtorno do Espectro Autista , Transtorno Autístico , Criança , Humanos , Transtorno do Espectro Autista/psicologia , Pupila , Emoções , Atenção , Fixação Ocular
11.
Sensors (Basel) ; 24(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38544022

RESUMO

Gaze and pupil metrics are used to represent higher cognitive processes in a variety of contexts. One growing area of research is the real-time assessment of workload and corresponding effort in gamified or simulated cognitive and motor tasks, which will be reviewed in this paper. While some measurements are consistent across studies, others vary and are likely dependent on the nature of the effort required by the task and the resulting changes in arousal. Pupil diameter is shown to consistently increase with task effort and arousal; however, the valence of arousal must be considered. In many cases, measures of pupil diameter were sensitive to both excessive and insufficient challenge. Overall, it is evident that gaze and pupil metrics are valuable to assess the cognitive state during gamified and simulated tasks, and further research is indicated regarding their use in clinical populations in rehabilitation to inform optimally engaging interventions.


Assuntos
Pupila , Carga de Trabalho , Carga de Trabalho/psicologia , Nível de Alerta
12.
Sci Rep ; 14(1): 6097, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38480839

RESUMO

We recently showed that the gain of the pupillary light response depends on numerosity, with weaker responses to fewer items. Here we show that this effect holds when the stimuli are physically identical but are perceived as less numerous due to numerosity adaptation. Twenty-eight participants adapted to low (10 dots) or high (160 dots) numerosities and subsequently watched arrays of 10-40 dots, with variable or homogeneous dot size. Luminance was constant across all stimuli. Pupil size was measured with passive viewing, and the effects of adaptation were checked in a separate psychophysical session. We found that perceived numerosity was systematically lower, and pupillary light responses correspondingly smaller, following adaptation to high rather than low numerosities. This is consistent with numerosity being a primary visual feature, spontaneously encoded even when task irrelevant, and affecting automatic and unconscious behaviours like the pupillary light response.


Assuntos
Pupila , Visão Ocular , Humanos , Conceitos Matemáticos , Inconsciência , Luz
13.
Clin Neurol Neurosurg ; 239: 108215, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447480

RESUMO

INTRODUCTION: Assessment of the pupillary light reflex (PLR) is key in intensive care monitoring of neurosurgical patients, particularly for monitoring intracranial pressure (ICP). Quantitative pupillometry using a handheld pupillometer is a reliable method for PLR assessment. However, many variables are derived from such devices. We therefore aimed to assess the performance of these variables at monitoring ICP. METHODS: Sedated patients admitted to neurocritical care in a tertiary neurosurgical centre with invasive ICP monitoring were included. Hourly measurement of ICP, subjective pupillometry (SP) using a pen torch device, and quantitative pupillometry (QP) using a handheld pupillometer were performed. RESULTS: 561 paired ICP, SP and QP pupillary observations from nine patients were obtained (1122 total pupillary observations). SP and QP had a moderate concordance for pupillary size (κ=0.62). SP performed poorly at detecting pupillary size changes (sensitivity=24%). In 40 (3.6%) observations, SP failed to detect a pupillary response whereas QP did. Moderate correlations with ICP were detected for maximum constriction velocity (MCV), dilation velocity (DV), and percentage change in pupillary diameter (%C). Discriminatory ability at an ICP threshold of >22 mmHg was moderate for MCV (AUC=0.631), DV (AUC=0.616), %C (AUC=0.602), and pupillary maximum size (AUC=0.625). CONCLUSION: QP is superior to SP at monitoring pupillary reactivity and changes to pupillary size. Although effect sizes were moderate to weak across assessed variables, our data indicates MCV and %C as the most sensitive variables for monitoring ICP. Further study is required to validate these findings and to establish normal range cut-offs for clinical use.


Assuntos
Pressão Intracraniana , Reflexo Pupilar , Humanos , Reflexo Pupilar/fisiologia , Estudos Prospectivos , Pressão Intracraniana/fisiologia , Pupila/fisiologia , Cuidados Críticos
14.
Trends Hear ; 28: 23312165241232551, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549351

RESUMO

In daily life, both acoustic factors and social context can affect listening effort investment. In laboratory settings, information about listening effort has been deduced from pupil and cardiovascular responses independently. The extent to which these measures can jointly predict listening-related factors is unknown. Here we combined pupil and cardiovascular features to predict acoustic and contextual aspects of speech perception. Data were collected from 29 adults (mean  =  64.6 years, SD  =  9.2) with hearing loss. Participants performed a speech perception task at two individualized signal-to-noise ratios (corresponding to 50% and 80% of sentences correct) and in two social contexts (the presence and absence of two observers). Seven features were extracted per trial: baseline pupil size, peak pupil dilation, mean pupil dilation, interbeat interval, blood volume pulse amplitude, pre-ejection period and pulse arrival time. These features were used to train k-nearest neighbor classifiers to predict task demand, social context and sentence accuracy. The k-fold cross validation on the group-level data revealed above-chance classification accuracies: task demand, 64.4%; social context, 78.3%; and sentence accuracy, 55.1%. However, classification accuracies diminished when the classifiers were trained and tested on data from different participants. Individually trained classifiers (one per participant) performed better than group-level classifiers: 71.7% (SD  =  10.2) for task demand, 88.0% (SD  =  7.5) for social context, and 60.0% (SD  =  13.1) for sentence accuracy. We demonstrated that classifiers trained on group-level physiological data to predict aspects of speech perception generalized poorly to novel participants. Individually calibrated classifiers hold more promise for future applications.


Assuntos
Pupila , Percepção da Fala , Adulto , Humanos , Pupila/fisiologia , Percepção da Fala/fisiologia , Inteligibilidade da Fala/fisiologia
15.
PLoS One ; 19(3): e0299064, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38517869

RESUMO

PURPOSE: This study aimed to assess the repeatability of intraocular lens (IOL) decentration measurements obtained through Pentacam, based on corneal topographic axis (CTA) and pupillary axis (PA), and to evaluate the level of agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. METHODS: In this prospective observational case series, three measurements were performed with Pentacam to evaluate the repeatability of the measurements. The analysis included the calculation of the mean and standard deviations (SD), conducting a repeated measures analysis of variance (rANOVA), and determining an intraclass correlation coefficient (ICC) to assess the repeatability of the measurements. Moreover, Bland-Altman analysis was employed to assess the agreement between Pentacam and OPD-Scan III devices in measuring IOL decentration. IOL decentration measurements were obtained with respect to both CTA and PA. RESULTS: A total of 40 eyes from 40 patients were analyzed. The rANOVA revealed no significant difference among three consecutive measurements of IOL decentration obtained with Pentacam. The mean SD of all parameters ranged from 0.04 mm to 0.07 mm. With CTA as the reference axis, the ICC values for Pentacam measurements of IOL decentration were 0.82 mm for the X-axis, 0.76 mm for the Y-axis, and 0.82 mm for spatial distance. When using PA as the reference axis, the corresponding ICC values were 0.87, 0.89, and 0.77, respectively. The 95% limits of agreement for all IOL decentration measurements were wide when comparing Pentacam and OPD-Scan III. CONCLUSIONS: Pentacam demonstrated high repeatability in measuring IOL decentration with respect to both CTA and PA. However, due to poor agreement between Pentacam and OPD-Scan III measurements, caution should be exercised when using data interchangeably between the two devices.


Assuntos
Lentes Intraoculares , Humanos , Córnea , Topografia da Córnea , Olho Artificial , Pupila , Reprodutibilidade dos Testes
16.
Optom Vis Sci ; 101(3): 157-163, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546757

RESUMO

SIGNIFICANCE: Validation of new biometry instruments against the gold standard and establishing repeatability are important before being utilized for clinical and research applications. PURPOSE: This study aimed to investigate intersession repeatability of the MYAH optical biometer and corneal topographer and examine agreement with the Lenstar LS900 optical biometer in healthy young adults. METHODS: Forty participants (mean age, 25.2 ± 3.1 years) presented for two visits, 2 to 4 days apart. At each visit, measurements for right eyes were collected with the MYAH and Lenstar LS 900 and included axial length, corneal power, white-to-white distance, and pupil diameter. Bland-Altman analysis was used to assess the intrasession agreement between the MYAH and Lenstar for each parameter and intersession repeatability for the two devices. For each device, coefficient of variation and intraclass correlation coefficient were calculated, and paired t tests between visits were performed to assess intersession repeatability. RESULTS: Good agreement (mean difference [95% limits of agreement]) between the MYAH and Lenstar was found for axial length (-0.01 [-0.07 to 0.04] mm), corneal power (-0.02 D [-0.15 to 0.19 d]), white-to-white distance (-0.13 [-0.43 to 0.17] mm), and pupil diameter (-0.27 [-0.79 to 1.33] mm). The limits of agreement, coefficient of variations, and intraclass correlation coefficients for MYAH-measured parameters were -0.04 to 0.04, 0.06%, and >0.99 for axial length; -0.24 to 0.19, 0.18%, and >0.99 for corneal power; -1.05 to 1.15, 0.57%, and 0.96 for white-to-white distance; and -0.17 to 0.21, 7.0%, and 0.76 for pupil diameter, with no significant difference between visits (p>0.05 for all), indicating good intersession repeatability. Similar intersession repeatability was also noted for Lenstar. CONCLUSIONS: Findings show good intersession repeatability of the MYAH and good agreement with the Lenstar for axial length, corneal power, and white-to-white distance in young adults. Pupil diameter was more variable, likely due to the dynamic nature of the pupil. This study provides validation and supports the use of the MYAH for ocular biometry.


Assuntos
Biometria , Córnea , Adulto Jovem , Humanos , Adulto , Pupila
17.
IEEE Trans Vis Comput Graph ; 30(5): 2077-2086, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38437077

RESUMO

Eye tracking has shown great promise in many scientific fields and daily applications, ranging from the early detection of mental health disorders to foveated rendering in virtual reality (VR). These applications all call for a robust system for high-frequency near-eye movement sensing and analysis in high precision, which cannot be guaranteed by the existing eye tracking solutions with CCD/CMOS cameras. To bridge the gap, in this paper, we propose Swift-Eye, an offline precise and robust pupil estimation and tracking framework to support high-frequency near-eye movement analysis, especially when the pupil region is partially occluded. Swift-Eye is built upon the emerging event cameras to capture the high-speed movement of eyes in high temporal resolution. Then, a series of bespoke components are designed to generate high-quality near-eye movement video at a high frame rate over kilohertz and deal with the occlusion over the pupil caused by involuntary eye blinks. According to our extensive evaluations on EV-Eye, a large-scale public dataset for eye tracking using event cameras, Swift-Eye shows high robustness against significant occlusion. It can improve the IoU and F1-score of the pupil estimation by 20% and 12.5% respectively, compared with the second-best competing approach, when over 80% of the pupil region is occluded by the eyelid. Lastly, it provides continuous and smooth traces of pupils in extremely high temporal resolution and can support high-frequency eye movement analysis and a number of potential applications, such as mental health diagnosis, behaviour-brain association, etc. The implementation details and source codes can be found at https://github.com/ztysdu/Swift-Eye.


Assuntos
Algoritmos , Movimentos Oculares , Gráficos por Computador , Piscadela , Pupila
18.
Int J Psychophysiol ; 198: 112325, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447701

RESUMO

Advances in wearable sensor technologies can be leveraged to investigate behavioral and physiological responses in task-induced stress environments. Reliable and valid multidimensional assessments are required to detect stress given its multidimensional nature. This study investigated the effect of recurrent task-induced acute stress on task performance, vagally mediated heart variability measures (vmHRV) and task-evoked pupillary response (TEPR). Task performance, vmHRV measures, and TEPR were collected from 32 study participants while they performed a computer-based task in a recurrent task-induced acute stress environment. Mixed-effects modeling was used to assess the sensitivity of each outcome variable to experimental conditions. Repeated measures correlation tests were used to examine associations between outcome variables. Task performance degraded under stress. vmHRV measures were lower in the stress conditions relative to the no stress conditions. TEPR was found to be higher in the stress conditions compared to the no stress conditions. Task performance was negatively associated with the vmHRV measures, and degraded task performance was linked to increased TEPR in the stress conditions. There were positive associations between vmHRV measures. TEPR was negatively associated with vmHRV measures. Although task-induced stress degrades task performance, recurrent exposure to that stress could alter this effect via habituation. Further, our findings suggest that vmHRV measures and TEPR are sensitive enough to quantify psychophysiological responses to recurrent task-induced stress.


Assuntos
Pupila , Análise e Desempenho de Tarefas , Humanos , Pupila/fisiologia , Frequência Cardíaca/fisiologia , Psicofisiologia
19.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454381

RESUMO

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Assuntos
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Acuidade Visual , Pupila , Topografia da Córnea
20.
Can J Anaesth ; 71(5): 611-618, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504035

RESUMO

PURPOSE: The pupil displays chaotic oscillations, also referred to as pupillary unrest in ambient light (PUAL). As pain has previously been shown to increase pupillary unrest, the quantitative assessment of PUAL has been considered a possible tool to identify and quantify pain. Nevertheless, PUAL is affected by various states, such as vigilance, cognitive load, or emotional arousal, independent of pain. Furthermore, systematically applied opioids are known to reduce PUAL, thus potentially limiting its usefulness to detect pain or changes in pain intensity. To test the hypothesis that PUAL can reliably identify changes in pain intensity in a clinical setting, we measured PUAL in patients experiencing substantial pain relief when regional anesthesia interventions were applied after surgery. METHODS: We conducted an observational study at an academic surgery centre following institutional review board approval. Eighteen patients with unsatisfactory pain control following surgery underwent regional anesthesia procedures to improve pain control. We used infrared pupillometry to assess pupillary unrest before and after the regional block. We then compared the changes in pupillary unrest with the changes in pain scores (numeric rating scale [NRS], range 0-10). RESULTS: Eighteen patients received epidural anesthesia (n = 14) or peripheral nerve blocks (n = 4), resulting in improvement of mean (standard deviation [SD]) NRS pain scores from 7.2 (1.7) to 1.9 (1.8) (difference in means, -2.2; 95% confidence interval [CI], -6.3 to -4.1; P < 0.001). Nevertheless, pupillary unrest did not change as pain decreased; the mean (SD) PUAL was 0.113 (0.062) before analgesia and 0.112 (0.068) after analgesia (difference in means, -0.001; 95% CI, -0.018 to 0.015; P = 0.88). CONCLUSION: In this prospective observational study, pupillometric measurements of pupillary unrest did not identify changes in pain intensity in a postoperative, predominantly opioid-exposed patient population. While the sample size was small, the use of measurements of pupillary unrest to detect and quantify pain has to be questioned.


RéSUMé: OBJECTIF: La pupille affiche des oscillations chaotiques, également appelées fluctuations du diamètre pupillaire (FDP). Comme il a déjà été démontré que la douleur augmente les troubles pupillaires, l'évaluation quantitative des FDP a été envisagée comme outil potentiel pour identifier et quantifier la douleur. Néanmoins, les FDP sont affectées par divers états, tels que la vigilance, la charge cognitive ou l'excitation émotionnelle, indépendamment de la douleur. De plus, nous savons que l'application systématique d'opioïdes réduit les FDP, ce qui limite potentiellement leur utilité pour détecter la douleur ou les changements d'intensité de la douleur. Pour tester l'hypothèse selon laquelle les FDP permettent d'identifier de manière fiable les changements dans l'intensité de la douleur dans un cadre clinique, nous avons mesuré les FDP chez les patient·es manifestant un soulagement substantiel de la douleur lorsque des interventions d'anesthésie régionale ont été appliquées après la chirurgie. MéTHODE: Nous avons mené une étude observationnelle dans un centre de chirurgie universitaire après avoir obtenu l'approbation du comité d'éthique indépendant. Dix-huit patient·es dont le contrôle de la douleur n'était pas satisfaisant à la suite d'une intervention chirurgicale ont bénéficié d'interventions d'anesthésie régionale pour améliorer le contrôle de la douleur. Nous avons utilisé la pupillométrie infrarouge pour évaluer les fluctuations du diamètre pupillaire avant et après le bloc régional. Nous avons ensuite comparé les changements dans les fluctuations pupillaires avec les changements dans les scores de douleur (échelle d'évaluation numérique [EVA], plage de 0 à 10). RéSULTATS: Dix-huit patient·es ont reçu une anesthésie péridurale (n = 14) ou des blocs nerveux périphériques (n = 4), ce qui a entraîné une amélioration des scores de douleur moyens (écart type [ET]) sur l'EVA de 7,2 (1,7) à 1,9 (1,8) (différence de moyennes, −2,2 ; intervalle de confiance [IC] à 95 %, −6,3 à −4,1; P < 0,001). Néanmoins, les fluctuations du diamètre pupillaire n'ont pas changé à mesure que la douleur diminuait; la moyenne (ET) des FDP était de 0,113 (0,062) avant l'analgésie et de 0,112 (0,068) après l'analgésie (différence de moyennes, −0,001; IC 95 %, −0,018 à 0,015; P = 0,88). CONCLUSION: Dans cette étude observationnelle prospective, les mesures pupillométriques des fluctuations du diamètre pupillaire n'ont pas permis d'identifier de changements dans l'intensité de la douleur dans une population de patient·es postopératoires, principalement exposé·es aux opioïdes. Bien que la taille de l'échantillon soit petite, l'utilisation de mesures des fluctuations du diamètre pupillaire pour détecter et quantifier la douleur doit être remise en question.


Assuntos
Dor , Pupila , Humanos , Pupila/fisiologia , Medição da Dor/métodos , Analgésicos Opioides , Manejo da Dor
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...